ERAVAP
Vapour Pressure Tester (ASTM D5191, D6377, EN 13016)

- Full compliance with ASTM D5191, D6377, D6378, D6897, D4052, EN 13016-1/-2/-3, IP 394, IP 409, IP 481, ISO 12185, JIS K2258-2
- 2-in-1: simultaneous vapour pressure and density measurement in one portable analyser
- Patented X-oscillating metal U-tube (Hastelloy) density cell — DENS4052 module
- TVS™ – Temperature Verification Sensor for ASTM D5191 testing
- Pure Sampling™ valve technology minimises cross-contamination between samples
- Widest temperature range on the market: 0 °C to 120 °C, extendable to –20 °C with the low-temperature module
- Optional 10-position autosampler for high sample throughput
- Truly portable — suitable for both stationary and mobile laboratories
Product Overview
The Eralytics ERAVAP is a compact, highly precise and easy to use vapour pressure tester, known for unmatched precision, speed and versatility across the widest temperature range available on the market. A small footprint and true portability, even with an attached 10-position autosampler, make it the instrument of choice for both stationary and mobile laboratories.
ERAVAP measures in full compliance with ASTM D5191, ASTM D6377, ASTM D6378, ASTM D6897, ASTM D4052, EN 13016-1, EN 13016-2, EN 13016-3, GOST R 52340, IP 394, IP 409, IP 481, ISO 12185, JIS K2258-2, SH/T 0769, SH/T 0794 and SN/T 2932. ASTM D323, D1267, D2533, D2879, D4953, D5190 and D5482 are supported as correlation methods.
A ground-breaking option is the DENS4052 module: an ultra-light, temperature-controlled X-oscillating metal U-tube density cell that lets a single ERAVAP report vapour pressure and density from the same sample injection, in compliance with ASTM D4052 and ISO 12185.
The California Air Resources Board (CARB) relies on the precision of ERAVAP, as does the U.S. EPA, which uses it as a reference instrument for vapour pressure testing. ERAVAP is also field-proven by the US Army, with close to 100 installations in mobile laboratories worldwide.
Category
Fuel Properties (Flash Point, Vapour Pressure, Abel Closed Cup, Pensky-Martens, Cleveland Open Cup)
Supplier Page
Technical Specifications
| Technique | Triple expansion vapour pressure, piston-based with Peltier temperature control |
| Parameters | DVPE, RVP, ASVP, TVP, VPCR4, vapour/liquid ratio; density with DENS4052 module |
| Compliance Methods | ASTM D4052, D5188, D5191, D6377, D6378, D6897, EN 13016-1/-2/-3, GOST R 52340, IP 394, IP 409, IP 481, ISO 12185, JIS K2258-2, SH/T 0769, SH/T 0794, SN/T 2932 |
| Correlation Methods | ASTM D323, D1267, D2533, D2879, D4953, D5190, D5482 |
| Temperature Range | 0 °C to 120 °C (32 °F to 248 °F); –20 °C to 120 °C with low-temperature module |
| Pressure Range | 0–1 000 kPa (0–145 psi) |
| Precision | Repeatability r ≤ 0.15 kPa; Reproducibility R ≤ 0.50 kPa |
| Temperature Stability | ±0.01 °C |
| Sample Volume | Approx. 12 mL per measurement including rinsing cycles |
| Sample Introduction | Automated via built-in piston, with reusable 80 µm mesh filter; no external vacuum pump |
| Display | 8.4" multilingual colour touchscreen |
| Interfaces | Built-in PC with Ethernet, USB and RS232; LIMS connectivity; CSV and PDF output |
| Autosampler | Optional 10-position autosampler |